(Print) Use this randomly generated list as your call list when playing the game. There is no need to say the BINGO column name. Place some kind of mark (like an X, a checkmark, a dot, tally mark, etc) on each cell as you announce it, to keep track. You can also cut out each item, place them in a bag and pull words from the bag.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
Pressurizer Level decreases in uncontrolled manner
EHC malfunction with power fluctuations and greater than 15% RTP, then trip reactor. Less than 15% RTP trip turbine
Turbine / Generator high vibration and greater than 15% RTP, then trip reactor. Less than 15% RTP, trip turbine
Shutdown affected Unit within 8 hrs of exceeding 6.0 gpm RCP seal leakoff flow
RCP HIGH OR LOW LUBE OIL LEVEL - if oil level low out of sight - INITIATE a shutdown per IPO-003A/B (ramp to 20% and trip).
Earthquake - ground acceleration exceeded OBE, Shutdown both units to COLD SHUTDOWN.
PW water temp greater than 140EF and greater than 15% RTP, then trip reactor. Less than 15% RTP trip turbine
FWP Trip >700 MW
Manually trip RX prior to manual trip of RCP due to seal failure
SCR less than 765', prior to stopping CWPs
Trip of both MFPs
Loss main condenser vacuum and power greater than 10%. Less than 10% trip turbine.
Loss of feed and S/G level decreasing uncontrolled manner.
HDP Trip >800 MW
Loss TPCW and turbine not tripped
INADVERTENT CLOSURE OF AN HP OR LP STOP OR CONTROL VALVE - Reduce turbine load per IPO-003A/B until ALL operable HP control valve positions indicate less than 100% open
Outside generator capability curve and greater than 15% RTP, then trip reactor. Less than 15% RTP trip turbine
IF in MODE 1, 2, 3, OR 4 AND Instrument Air Header pressure decreases to 35 psig OR control of system(s) is lost
Manually trip RX prior to manual trip of RCP due to loss of seal injection and thermal barrier cooling
RCP trip
Alarms on Both Generator Core Monitors (GCMs) AND Gen Stat mon Temp Fault LIT, and power less than 900MW
Manually trip RX prior to manual trip of RCP due to seal inlet temp high
Multiple HTR MALF/Loss EXT STM >900 MW
-Rods stationary with rod insertion required
TPCW Head Tank Level Lo/decreasing and power greater than 50% ( P9), then trip reactor. Less than P9 trip turbine
More than one dropped rod
Manually trip RX prior to manual trip of RCP due to seal water bearing temp high
Grid frequency less than 57.2 Hz
No SSW Pumps running, prior to tripping RCPs
Manually trip RX prior to manual trip of RCP due to high vibration
Manually trip RX prior to manual trip of RCP due to operating outside RCP parameters
Turbine bearing metal temp outside parameters and greater than 15% RTP, then trip reactor. Less than 15% RTP trip turbine
PRZR Safety Valves OPEN - Pressurizer Pressure decreases in uncontrolled manner
Condensate Pump Trip >700 MW
Flooding condenser pit greater than 759'
CCW pump trip and SSW in unaffected train will not start.
Less than TWO circulating water pumps operating
Liquid level in-leakage faster than can be drained and greater than 15% RTP, then trip reactor. Less than 15% RTP trip turbine
Free!
Manually trip RX prior to manual trip of RCP due to motor bearing temp high
HP TURBINE CASING Delta T HIGH
Generator H2 pressure less than 45 psi and greater than 15% RTP, then trip reactor. Less than 15% RTP trip turbine
-Rod withdrawal with rod insertion demand AND rod motion required
-Rod motion with NO demand
LOSS OF ALL SAFETY CHILLED WATER COOLING - restoration of a Safety Chilled Water train expected in greater than 1 hour
Loss of C2 >800 MW
Negative Sequence Current greater than 12% and greater than 15% RTP, then trip reactor. Less than 15% RTP trip turbine
LP FW HTR Byp Vlv open >900 MW
Unable to restore CCW non-SFGD loop
Seal oil flow/temp trouble and greater than 15% RTP, then trip reactor. Less than 15% RTP trip turbine
Condenser tube leak with high SGBD sodium
RCS Tech Spec leakage exceeded
Grid frequency greater than 61.8 Hz
Loss of C3 >800 MW
-Rods moving in different direction simultaneously AND rod motion required
STEAM GENERATOR TUBE LEAKAGE GREATER THAN OR EQUAL TO 75 GPD - Reduce power to < 50% in 1 hour AND Be in MODE 3 in the next 2 hours.